DAVITEQ AMMONIA NH3 GAS SENSOR, 100 PPM, SERI-4 SENSOR SPECIFICATION MEASURING SPECIFICATION Sensor type Daviteq Seri-4 electrochemical gas sensor Nominal range 0-100 ppm Maximum overload 200 ppm Resolution 0.1 ppm T90 response time < 35 s Typical Baseline Range (pure air, 20°C) -3.0 ppm .. + 3.0 ppm Repeatability < 3% of reading Accuracy 5% of Reading Zero Stability 0 .. 0.2 ppm in pure Air, 20oC Temperature compensation Yes WORKING CONDITIONS Relative humidity range 15 % to 90 % RH non-condensing Temperature range -10 °C to 50 °C Pressure range Atmospheric ± 10% Humidity effect (Abrupt changes in rel. humidity causes a short-term transient signal) < 4 ppm SENSOR LIFETIME Expected Operation Life 2 years in the air Expected Long-Term Output Drift in air < 5 % of reading loss per 6 months CROSS SENSITIVITY DATA The table below does not claim to be complete. Interfering gases should not be used for calibration. Interfering Gas Concentration (ppm) Reading (ppm) Cl2 20 -55 CO 300 0 CO2 20000 0 H2 200 0 H2S 20 7 NO 20 -1 NO2 20 -20 SiH4 10 0 SO2 20 -7 Important Application Notes Long-term exposures at high concentrations of SO2, H2S, NO, NO2, and Cl2 can affect the performance characteristics.