Sample HTML table for troubleshooting 2
No.
Phenomena
Reason
Solution
1
The wireless transmitter is still running and sending data, however, all the measurement parameters are not updated with new values
The connection between the AG tilt sensor and the wireless transmitter is broken
Contact the manufacturer for repair or replacement
The battery is almost draining off
Check the battery status and replace it when necessary
2
The measured values are not as expected
The installation direction is not correct
Re-check the installation
The sensor is drifting
Contact the manufacturer for repair or replacement
The calibration position or calibration process is incorrect
Re-calibrate the device with right position and right process
3
The reading values are very noisy even though the sensor is in a standstill position.
The sensor AG tilt sensor got a problem
Contact the manufacturer for repair or replacement
External factors at installation location such as wind, vibration, temperature, sun, heat might affect the tilt value
External factors such as wind, vibration, temperature, sun, heat at installation location
4
The value of HW_Error equal 1
The lost connection between the AG sensor and the wireless transmitter
Contact the manufacturer for repair or replacement
The sensor AG sensor got a problem
Contact the manufacturer for repair or replacement