Product data sheet for Sensor elements
- Temperature Sensors
- Air flow sensors
- Internal Sensor Modules for Ambient Air Quality Monitor
- AMBIENT TEMPERTURE AND HUMIDITY SENSOR MODULE -ATH
- SOUND LEVEL SENSOR MBRTU-SL
- OPTICAL PARTICLE COUNTING SENSOR MBRTU-OPC
- OPTICAL PARTICLE PROFILER MAX-OPC-N3
- HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-O3
- HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-NO2
- HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO
- HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-SO2
- HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO2
- Ultrasonic Water Meter UWM
- Bulk Ultrasonic Water Meter BUW
- Infrared Fever Scanner IFS-HQ1
- pH Sensors
- WIND SPEED SENSOR WSP
- WIND DIRECTION SENSOR WDR
Temperature Sensors
New Page
Air flow sensors
Air Velocity Sensor AVS
SKU: AVS | Doc No: AVS-DS-EN-10 |
IntroductionAVS is the Air Velocity Sensor with DULP output with M12-Male connector, compatible with all kind of Wireless sensor node from Daviteq that support DULP signal.
|
Typical applications
|
Specification
Technology | thermal mass flow measurement |
Velocity range (m/s) | 0 .. 15 |
Accuracy | 5% |
Repeatability | 1% |
Resolution | 12 bit |
Response Time | 125 mSec |
Output | DULP |
Supply | 3.3VDC |
Operating temperature and humidity | -25 .. + 85 oC, 0 .. 100% RH (non condensing) |
Connector | M12-Male 4 pin |
Net Weight | max 500g |
Ordering Code
Item code | Descriptions |
AVS-15-P300 | AIR VELOCITY SENSOR, DULP OUTPUT, MAX 15M/S WITH 300MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR |
AVS-15-200 | DULP TYPE AIR VELOCITY SENSOR, MAX 15M/S WITH 200MM CORRUGATED CABLE, M12-MALE CONNECTOR |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
Air Flow Sensor AFD
SKU: AFD | Doc No: AFD-DS-EN-10 |
IntroductionAFD is the Air, Gas Velocity Sensor with DULP output with M12-Male connector, compatible with all kinds of Wireless sensor nodes from Daviteq that support DULP signal, for example, WS433-M12F, WSSFC-M12F, WSLRW-M12F
|
Typical applications
|
Specification
Technology | Differential Pressure |
Fluid to measure | Air, Nitrogen, Oxygen, Argon, CO2 |
Velocity range (m/s) | 4-29 (for Air) |
Velocity accuracy (m/s) | +/- 0.5 |
Max Static Pressure (barg) | Continuous 0.44 |
Burst pressure (barg) | 0.67 |
Sensor probe dimension | 12mm diameter, 200mm length |
Process connection | Sliding proprietary flange, come with Gasket |
Output | DULP |
Connector | M12-Male 4 pin |
Working temperature (oC) | -40 .. + 85 |
Working Humidity (%RH) | 0-95, non-condensed |
Net Weight | max 500g |
Ordering Code
Item code | Descriptions |
AFD-0200 | AIR FLOW SENSOR, DULP OUTPUT, 4-29M/S WITH 200MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR |
AFD-0500 | AIR FLOW SENSOR, DULP OUTPUT, 4-29M/S WITH 500MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
Internal Sensor Modules for Ambient Air Quality Monitor
These sensor modules are used for Ambient Air Quality Monitor like MAQM...
AMBIENT TEMPERTURE AND HUMIDITY SENSOR MODULE -ATH
Item code: MBRTU-ATH-11IR
Description: Internal sensor module for ambient temperature and humidity, Modbus output.
Used for: MAQM
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Sensor | Digital type, factory calibrated, outputs both Humidity & Temperature values |
Humidity measuring range & accuracy | 0 .. 100 %RH, +/- 3.0% RH (+/- 1.5%RH for ATH-15 version) |
Humidity resolution | 0.1% |
Temperature measuring range & accuracy | -40 .. + 85 oC, +/- 0.5 oC (+/- 0.1 oC for ATH-15 version) |
Temperature resolution | 0.1 oC |
Sensor Filter | 20um Alloy sintered filter |
Accessories | Rain-guard for outdoor installation |
Power supply | 9..36VDC, max 30mA |
SOUND LEVEL SENSOR MBRTU-SL
Item code: MBRTU-SL-01
Description: Internal Sensor module for Sound level, Modbus output.
Used for: MAQM and MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Sensor | Capacitive Microphone |
Measuring range | 30-130 dB(A) |
Frequency range | 20 - 12,500 Hz |
Resolution | 0.1 dB(A) |
Accuracy | +/- 0.5 dB(A) at 94 dB(A) and 1 KHz |
Working temperature | -20 .. + 60 oC |
Working humidity | 0 - 80% RH |
Power supply | 9..36VDC, max 30mA |
OPTICAL PARTICLE COUNTING SENSOR MBRTU-OPC
Item code: MBRTU-OPC-02I
Description: Internal Sensor module for measuring outdoor PM1.0, PM2.5, and PM10; Modbus output.
Used for: MAQM
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Laser light scattered method for PM1.0, PM2.5 and PM10 |
Particle range | 0.3 to 12.4 um |
Detection limit (PM10) | 0.01 ug/m3 to 1500 mg/m3 |
Resolution | 0.01 ug/m3 |
Accuracy | +/- 10% of Reading value |
Sample flowrate | 240 mL/min |
Laser Classification | Class 1 |
Power supply | 9..36VDC, max 30mA |
OPTICAL PARTICLE PROFILER MAX-OPC-N3
Item code: MAX-OPC-N3
Description: Internal Sensor module for measuring outdoor PM1.0, PM2.5, and PM10; Modbus output.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Laser light scattered method for PM1.0, PM2.5 and PM10 |
Particle range | 0.3 to 40 um |
Detection limit (PM1) | 0.01 ug/m3 to 200 ug/m3 |
Detection limit (PM2.5) | 0.01 ug/m3 to 2000 ug/m3 |
Detection limit (PM10) | 0.01 ug/m3 to 2000 ug/m3 |
Resolution | 0.01 ug/m3 |
Accuracy | +/- 10% of Reading value |
Sample flowrate | 5.5 L/min |
Working Temperature | -10 .. + 50 oC |
Working Humidity | 0..95% RH non-condensing, continuous |
Laser Classification | Class 1 |
Power supply | 9..36VDC, max 30mA |
HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-O3
Item code: MAX-O3-C5
Description: Internal Sensor module for measuring Ozone gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Electro-chemical |
Measurement range | 0-5 ppm |
Overload | 50 ppm |
Resolution | 0.001 ppm |
Lower Detectable Limit | 0.001 ppm |
Accuracy | +/- 2% of Reading value |
Linearity |
< 0.1% of Full scale |
Response Time (T80) | < 60s |
Operating Pressure | Atmospheric ± 10% |
Working Temperature | -40 .. + 50 oC |
Working Humidity | 15..90% RH non-condensing, continuous |
Sensor Life Time | 2 years in clean air |
Drift in Air | < 2 % signal loss per month |
Power supply | 9..36VDC, max 30mA |
CROSS SENSITIVITY DATA
The table below does not claim to be complete. Interfering gases should not be used for calibration.
HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-NO2
Item code: MAX-NO2-C20
Description: Internal Sensor module for measuring NO2 gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Electro-chemical |
Measurement range | 0-20 ppm |
Overload | 200 ppm |
Resolution | 0.001 ppm |
Lower Detectable Limit | 0.001 ppm |
Accuracy | +/- 2% of Reading value |
Linearity |
< 0.1% of Full scale |
Response Time (T90) | < 60s |
Operating Pressure | Atmospheric ± 10% |
Working Temperature | -40 .. + 50 oC |
Working Humidity | 15..90% RH non-condensing, continuous |
Sensor Life Time | 2 years in clean air |
Drift in Air | < 2 % signal loss per month |
Power supply | 9..36VDC, max 30mA |
CROSS SENSITIVITY DATA
The table below does not claim to be complete. Interfering gases should not be used for calibration.
HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO
Item code: MAX-CO-C1000
Description: Internal Sensor module for measuring CO gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Electro-chemical |
Measurement range | 0-1000 ppm |
Overload | 2000 ppm |
Resolution | 0.001 ppm |
Lower Detectable Limit | 0.04 ppm |
Accuracy | +/- 2% of Reading value |
Linearity |
< 0.1% of Full scale |
Response Time (T90) | < 35s |
Operating Pressure | Atmospheric ± 10% |
Working Temperature | -40 .. + 50 oC |
Working Humidity | 15..90% RH non-condensing, continuous |
Sensor Life Time | 3 years in clean air |
Drift in Air | < 2 % signal loss per month |
Power supply | 9..36VDC, max 30mA |
CROSS SENSITIVITY DATA
The table below does not claim to be complete. Interfering gases should not be used for calibration.
HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-SO2
Item code: MAX-SO2-C20
Description: Internal Sensor module for measuring SO2 gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Electro-chemical |
Measurement range | 0-20 ppm |
Overload | 100 ppm |
Resolution | 0.001 ppm |
Lower Detectable Limit | 0.009 ppm |
Accuracy | +/- 2% of Reading value |
Linearity |
< 0.1% of Full scale |
Response Time (T90) | < 15s |
Operating Pressure | Atmospheric ± 10% |
Working Temperature | -20 .. + 50 oC |
Working Humidity | 15..90% RH non-condensing, continuous |
Sensor Life Time | 2 years in clean air |
Drift in Air | < 2 % signal loss per month |
Power supply | 9..36VDC, max 30mA |
CROSS SENSITIVITY DATA
The table below does not claim to be complete. Interfering gases should not be used for calibration.
HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO2
Item code: MAX-CO2-LP5000
Description: Internal Sensor module for measuring CO2 gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | NDIR |
Measurement range | 0-5000 ppm |
Overload | 100 % |
Resolution | 1 ppm |
Lower Detectable Limit | 10 ppm |
Accuracy | +/- 30 ppm + 3% of reading |
Linearity |
< 0.1% of Full scale |
Response Time (T90) | < 30s |
Operating Pressure | 500 mbar to 2 bar absolute |
Working Temperature | 0 .. + 50 oC |
Working Humidity | 0..95% RH non-condensing, continuous |
Sensor Life Time | 10 years in clean air |
Pressure Dependence | 0.14% signal per mbar deviation from 1013 mbar, 950-1050mba |
Power supply | 9..36VDC, max 30mA |
Ultrasonic Water Meter UWM
SKU: UWM | Doc No: UWM-DS-EN-10 |
Introduction
UWM Ultrasonic water meter is a new type of water meter that detects the time difference caused by the change of velocity when the ultrasonic beam propagates in the opposite direction of the water, and analyzes and processes the flow rate of water to further calculate the flow of water..
Dimension Drawings |
Features
Dimensions |
Specification

LoRaWAN Specification
Data rate | 250bps .. 5470bps |
Antenna | Internal Antenna 2.67 dbi |
Battery | 02 x AA size 1.5VDC, battery not included |
RF Frequency and Power | 860..930Mhz, +14 .. +20 dBm, configurable for zones: EU868, IN865, RU864, KR920, AS923, AU915, US915 |
Protocol | LoRaWAN class A |
Data sending modes | interval time, alarm occurred and manually triggering by magnetic key |
RF Module complies to | ETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD-T108 (Japan) |
Working temperature | 1oC..+65oC |
Housing | Polycarbonate plastic, IP68 |
Ordering codes
Item code | Descriptions |
UWM-15-LRW-8-01 | Ultrasonic Water Meter DN15 with LoRaWAN connectivity, IP68, 860-870 Mhz for EU868, IN865, RU864 |
UWM-15-LRW-9-01 | Ultrasonic Water Meter DN15 with LoRaWAN connectivity, IP68, 900-930 Mhz for KR920, AS923, AU915, US915 |
* Replace 15 by 20, 25, 32, 40 for different sizes |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
Bulk Ultrasonic Water Meter BUW
SKU: BUW | Doc No: BUW-DS-EN-10 |
Specification
LoRaWAN Specification
Data rate | 250bps .. 5470bps |
Antenna | Internal Antenna 2.67 dbi |
Battery | 02 x AA size 1.5VDC, battery not included |
RF Frequency and Power | 860..930Mhz, +14 .. +20 dBm, configurable for zones: EU868, IN865, RU864, KR920, AS923, AU915, US915 |
Protocol | LoRaWAN class A |
Data sending modes | interval time, alarm occurred and manually triggering by magnetic key |
RF Module complies to | ETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD-T108 (Japan) |
Working temperature | 1oC..+65oC |
Housing | Polycarbonate plastic, IP68 |
Ordering codes
Item code | Descriptions |
BUW-050-LRW-8-01 | Bulk Ultrasonic Water Meter DN50 with LoRaWAN connectivity, IP68, 860-870 Mhz for EU868, IN865, RU864 |
BUW-050-LRW-9-01 | Bulk Ultrasonic Water Meter DN50 with LoRaWAN connectivity, IP68, 900-930 Mhz for KR920, AS923, AU915, US915 |
* Replace 050 by 065 .. 300 for different sizes |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
Infrared Fever Scanner IFS-HQ1
SKU: IFS-HQ1 | Doc No: IFS-HQ1-DS-EN-10 |
Specification
Ordering codes
Item code | Descriptions |
IFS-HQ1-01 |
Infrared Fever Scanner for max 20 people, QVGA 384x288, 17μm, c/w Windows SW, Thermal + Visible imaging, USB3.0, Lens 9.7mm(f/1.0), Frame rate <30Hz, included Black body, NOT included stand and computer |
STAND-01 | Tripod with Arm bar |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
pH Sensors
Datasheet for all kinds of pH Sensor
Process Flat pH Sensor H087
SKU: H087 | Doc No: H087-DS-EN-10 |
IntroductionH087 is a popular general purpose in-line (continuous measurement) electrode offering affordable, flat sensor application coverage for many water applications such as drinking water, industrial water, aquaculture, tank installations or related applications. The flat surface sensor is often referred to as "self-cleaning" when installed in a process stream since the water flow has a tendency to "shear off" biofouling and other debris from the sensor surface.
3/4" NPT threads on both front & back; Flat surface sensor with "self-cleaning" properties; Built-in temperature sensor Pt100.
|
Typical applications
|
Specification
Sensing Technology | Glass, combine electrode with Pt100 temperature sensor |
Measuring range | pH 0 .. 14 |
Resolution | pH 0.1 |
Accuracy | +/- 0.1 |
Working temperature | 0 .. 100 oC (compensated) |
Working pressure | 0 .. 100 psig |
Process connection | 3/4" NPT both ends |
Wetted parts | PVC |
Sensor Cable | 6m with BNC connector |
Rating | IP68 |
Sensor Dimension | D27 x 172 (mm) |
Sensor net weight | < 200 grams |
Ordering Code
Item code | Descriptions |
H087-0020 |
PH SENSOR COMBO, IN-LINE, 3/4NPT PH COMBO, IN-LINE, CPVC, 3/4"NPT, ASGV FLAT, PT100 OHM, DJ, AG/AGCL, GEL, CE, 20F CABLE, BNC & T |
Link for full datasheet: https://filerun.daviteq.com/wl/?id=ZfgOqaUaPovTmC9NM9sragDDe60lrzbQ
Link for manual:
Daviteq Technologies Inc
|
Process pH Sensor PH12
SKU: H087 | Doc No: PH12-DS-EN-10 |
IntroductionPH12 is a popular general purpose in-line (continuous measurement) electrode offering affordable sensor application coverage for many water applications such as drinking water, industrial water, aquaculture, tank installations or related applications.
3/4" NPT threads on both front & back; Built-in temperature sensor Pt100.
|
Typical applications
|
Specification
Sensing Technology | Glass, combine electrode with Pt100 temperature sensor |
Measuring range | pH 0 .. 14 |
Resolution | pH 0.1 |
Accuracy | +/- 0.1 |
Working temperature | 0 .. 60 oC (compensated) |
Working pressure | 0 .. 100 psig |
Process connection | 3/4" NPT both ends |
Wetted parts | PPS/PC |
Sensor Cable | 5m with BNC connector |
Rating | IP68 |
Sensor Dimension | D27 x 172 (mm) |
Sensor net weight | < 200 grams |
Ordering Code
Item code | Descriptions |
PH12-01 |
PH SENSOR COMBO, IN-LINE, 3/4NPT PH COMBO, IN-LINE, PPS/PC, 3/4"NPT, PT100, DJ, AG/AGCL, GEL, CE, 5m CABLE, BNC & T |
Daviteq Technologies Inc
|
WIND SPEED SENSOR WSP
SKU: WSP | Doc No: WSP-DS-EN-10 |
IntroductionWSP is the Wind Speed Sensor with carbon fiber material. Sensor with high weather resistance, high durability, corrosion resistance and water resistance.
|
Typical applications
|
Specification
Measure range |
0-70m/s( Other can be custom made) |
Start wind speed |
0.2m/s |
Response time |
<0.5s |
Resolution |
0.1m/s |
Accuracy |
±(0.2+0.03V)m/s, V means wind speed |
Output |
0..5VDC |
Power supply |
12..24VDC |
Power consumption |
≤0.3W |
Working temperature |
-20~60℃ |
Working humidity |
≤100%RH |
Cable specifications |
2m 3-wire system (analog signal) |
Ordering Code
Item code | Descriptions |
WSP-01-ANALOG
|
WIND SPEED SENSOR, 0-70 M/S, CARBON FIBER, 0-5VDC OUTPUT, 12-24VDC, WITH CABLE AND CONNECTOR
|
MBRTU-WSP-01
|
WIND SPEED SENSOR, CARBON FIBER CUPS, RS485/MODBUSRTU, 12-24VDC SUPPLY, 0-45M/S, IP65 |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|
WIND DIRECTION SENSOR WDR
SKU: WDR | Doc No: WDR-DS-EN-10 |
IntroductionThe wind direction sensor is used to measure the direction value of the wind and convert it into an electrical signal, which can be directly transmitted to the recording device for processing. The sensor housing is made of polycarbonate environmental protection material, with very small dimensional tolerances and high surface accuracy. The wind direction sensor adopts low inertia wind vane and precision potentiometer, with high sensitivity and high precision.
|
Typical applications
|
Specification
Measure range |
0-360 degree |
Start wind |
0.5 m/s |
Resolution |
0.1 degree |
Accuracy |
+/- 1 degree |
Maximum turning radius |
200mm |
Output |
0..5VDC or RS485 ModbusRTU |
Power supply |
12..24VDC |
Power consumption |
≤0.3W |
Working temperature |
-20~60℃ |
Working humidity |
≤100%RH |
Cable specifications |
2m 3-wire system (analog signal) |
Ordering Code
Item code | Descriptions |
WDR-01-ANALOG |
WIND DIRECTION SENSOR, 0-360 DEGREE, CARBON FIBER, 0-5VDC OUTPUT, 12-24VDC, WITH CABLE AND CONNECTOR |
MBRTU-WDR-01 |
WIND DIRECTION SENSOR, 0-360 DEGREE, CARBON FIBER, MODBUSRTU RS485 OUTPUT, 12-24VDC, IP65 |
Link for full datasheet:
Link for manual:
Daviteq Technologies Inc
|