Product data sheet for Sensor elements Temperature Sensors New Page Air flow sensors Air Velocity Sensor AVS SKU: AVS Doc No: AVS-DS-EN-10 Introduction AVS is the Air Velocity Sensor with DULP output with M12-Male connector, compatible with all kind of Wireless sensor node from Daviteq that support DULP signal. No moving parts; Excellent repeatability (1% FS); “Solid state” sensing core (no surface cavity or fragile membrane) resistant to clogging and pressure shock Typical applications Data Center Thermal Management; HVAC VAV Damper Control; HVAC Filter Monitoring. Specification Technology thermal mass flow measurement Velocity range (m/s) 0 .. 15 Accuracy 5% Repeatability 1% Resolution 12 bit Response Time 125 mSec Output DULP Supply 3.3VDC Operating temperature and humidity -25 .. + 85 oC, 0 .. 100% RH (non condensing) Connector M12-Male 4 pin Net Weight max 500g Ordering Code Item code Descriptions AVS-15-P300 AIR VELOCITY SENSOR, DULP OUTPUT, MAX 15M/S WITH 300MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR AVS-15-200 DULP TYPE AIR VELOCITY SENSOR, MAX 15M/S WITH 200MM CORRUGATED CABLE, M12-MALE CONNECTOR Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com Air Flow Sensor AFD SKU: AFD Doc No: AFD-DS-EN-10 Introduction AFD is the Air, Gas Velocity Sensor with DULP output with M12-Male connector, compatible with all kinds of Wireless sensor nodes from Daviteq that support DULP signal, for example, WS433-M12F, WSSFC-M12F, WSLRW-M12F No moving parts; Excellent repeatability (2% FS); Can be used for "Wet" gas; Adjustable stem length to suit different pipe or duct sizes Typical applications Data Center Thermal Management; HVAC VAV Damper Control; HVAC Filter Monitoring Using for measuring the flow of Air, Argon, CO2, Nitrogen, Oxygen Specification Technology Differential Pressure Fluid to measure Air, Nitrogen, Oxygen, Argon, CO2 Velocity range (m/s) 4-29 (for Air) Velocity accuracy (m/s) +/- 0.5 Max Static Pressure (barg) Continuous 0.44 Burst pressure (barg) 0.67 Sensor probe dimension 12mm diameter, 200mm length Process connection Sliding proprietary flange, come with Gasket Output DULP Connector M12-Male 4 pin Working temperature (oC) -40 .. + 85 Working Humidity (%RH) 0-95, non-condensed Net Weight max 500g Ordering Code Item code Descriptions AFD-0200 AIR FLOW SENSOR, DULP OUTPUT, 4-29M/S WITH 200MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR AFD-0500 AIR FLOW SENSOR, DULP OUTPUT, 4-29M/S WITH 500MM LENGTH SLIDING PROBE, FLANGE, M12-MALE CONNECTOR Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com Internal Sensor Modules for Ambient Air Quality Monitor These sensor modules are used for Ambient Air Quality Monitor like MAQM... AMBIENT TEMPERTURE AND HUMIDITY SENSOR MODULE -ATH Item code: MBRTU-ATH-11IR Description: Internal sensor module for ambient temperature and humidity, Modbus output. Used for: MAQM SENSOR SPECIFICATION MEASURING SPECIFICATION Sensor Digital type, factory calibrated, outputs both Humidity & Temperature values Humidity measuring range & accuracy 0 .. 100 %RH, +/- 3.0% RH (+/- 1.5%RH for ATH-15 version) Humidity resolution 0.1% Temperature measuring range & accuracy -40 .. + 85 oC, +/- 0.5 oC (+/- 0.1 oC for ATH-15 version) Temperature resolution 0.1 oC Sensor Filter 20um Alloy sintered filter Accessories Rain-guard for outdoor installation Power supply 9..36VDC, max 30mA SOUND LEVEL SENSOR MBRTU-SL Item code: MBRTU-SL-01 Description: Internal Sensor module for Sound level, Modbus output. Used for: MAQM and MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Sensor Capacitive Microphone Measuring range 30-130 dB(A) Frequency range 20 - 12,500 Hz Resolution 0.1 dB(A) Accuracy +/- 0.5 dB(A) at 94 dB(A) and 1 KHz Working temperature -20 .. + 60 oC Working humidity 0 - 80% RH Power supply 9..36VDC, max 30mA OPTICAL PARTICLE COUNTING SENSOR MBRTU-OPC Item code: MBRTU-OPC-02I Description: Internal Sensor module for measuring outdoor PM1.0, PM2.5, and PM10; Modbus output. Used for: MAQM SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Laser light scattered method for PM1.0, PM2.5 and PM10 Particle range 0.3 to 12.4 um Detection limit (PM10) 0.01 ug/m3 to 1500 mg/m3 Resolution 0.01 ug/m3 Accuracy +/- 10% of Reading value Sample flowrate 240 mL/min Laser Classification Class 1 Power supply 9..36VDC, max 30mA OPTICAL PARTICLE PROFILER MAX-OPC-N3 Item code: MAX-OPC-N3 Description: Internal Sensor module for measuring outdoor PM1.0, PM2.5, and PM10; Modbus output. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Laser light scattered method for PM1.0, PM2.5 and PM10 Particle range 0.3 to 40 um Detection limit (PM1) 0.01 ug/m3 to 200 ug/m3 Detection limit (PM2.5) 0.01 ug/m3 to 2000 ug/m3 Detection limit (PM10) 0.01 ug/m3 to 2000 ug/m3 Resolution 0.01 ug/m3 Accuracy +/- 10% of Reading value Sample flowrate 5.5 L/min Working Temperature -10 .. + 50 oC Working Humidity 0..95% RH non-condensing, continuous Laser Classification Class 1 Power supply 9..36VDC, max 30mA HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-O3 Item code: MAX-O3-C5 Description: Internal Sensor module for measuring Ozone gas. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Electro-chemical Measurement range 0-5 ppm Overload 50 ppm Resolution 0.001 ppm Lower Detectable Limit 0.001 ppm Accuracy +/- 2% of Reading value Linearity < 0.1% of Full scale Response Time (T80) < 60s Operating Pressure Atmospheric ± 10% Working Temperature -40 .. + 50 oC Working Humidity 15..90% RH non-condensing, continuous Sensor Life Time 2 years in clean air Drift in Air < 2 % signal loss per month Power supply 9..36VDC, max 30mA CROSS SENSITIVITY DATA The table below does not claim to be complete. Interfering gases should not be used for calibration. Important Application Notes: NO readily forms NO2 in the presence of O2. HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-NO2 Item code: MAX-NO2-C20 Description: Internal Sensor module for measuring NO2 gas. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Electro-chemical Measurement range 0-20 ppm Overload 200 ppm Resolution 0.001 ppm Lower Detectable Limit 0.001 ppm Accuracy +/- 2% of Reading value Linearity < 0.1% of Full scale Response Time (T90) < 60s Operating Pressure Atmospheric ± 10% Working Temperature -40 .. + 50 oC Working Humidity 15..90% RH non-condensing, continuous Sensor Life Time 2 years in clean air Drift in Air < 2 % signal loss per month Power supply 9..36VDC, max 30mA CROSS SENSITIVITY DATA The table below does not claim to be complete. Interfering gases should not be used for calibration. Important Application Notes: HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO Item code: MAX-CO-C1000 Description: Internal Sensor module for measuring CO gas. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Electro-chemical Measurement range 0-1000 ppm Overload 2000 ppm Resolution 0.001 ppm Lower Detectable Limit 0.04 ppm Accuracy +/- 2% of Reading value Linearity < 0.1% of Full scale Response Time (T90) < 35s Operating Pressure Atmospheric ± 10% Working Temperature -40 .. + 50 oC Working Humidity 15..90% RH non-condensing, continuous Sensor Life Time 3 years in clean air Drift in Air < 2 % signal loss per month Power supply 9..36VDC, max 30mA CROSS SENSITIVITY DATA The table below does not claim to be complete. Interfering gases should not be used for calibration. Important Application Notes: HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-SO2 Item code: MAX-SO2-C20 Description: Internal Sensor module for measuring SO2 gas. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology Electro-chemical Measurement range 0-20 ppm Overload 100 ppm Resolution 0.001 ppm Lower Detectable Limit 0.009 ppm Accuracy +/- 2% of Reading value Linearity < 0.1% of Full scale Response Time (T90) < 15s Operating Pressure Atmospheric ± 10% Working Temperature -20 .. + 50 oC Working Humidity 15..90% RH non-condensing, continuous Sensor Life Time 2 years in clean air Drift in Air < 2 % signal loss per month Power supply 9..36VDC, max 30mA CROSS SENSITIVITY DATA The table below does not claim to be complete. Interfering gases should not be used for calibration. Important Application Notes: HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-CO2 Item code: MAX-CO2-LP5000 Description: Internal Sensor module for measuring CO2 gas. Used for: MAQM-MAX SENSOR SPECIFICATION MEASURING SPECIFICATION Measuring technology NDIR Measurement range 0-5000 ppm Overload 100 % Resolution 1 ppm Lower Detectable Limit 10 ppm Accuracy +/- 30 ppm + 3% of reading Linearity < 0.1% of Full scale Response Time (T90) < 30s Operating Pressure 500 mbar to 2 bar absolute Working Temperature 0 .. + 50 oC Working Humidity 0..95% RH non-condensing, continuous Sensor Life Time 10 years in clean air Pressure Dependence 0.14% signal per mbar deviation from 1013 mbar, 950-1050mba Power supply 9..36VDC, max 30mA Ultrasonic Water Meter UWM SKU: UWM Doc No: UWM-DS-EN-10 Introduction UWM Ultrasonic water meter is a new type of water meter that detects the time difference caused by the change of velocity when the ultrasonic beam propagates in the opposite direction of the water, and analyzes and processes the flow rate of water to further calculate the flow of water.. Dimension Drawings Features No mechanical movable parts, impurities in water can’t be affected, long service life. Wide measurement range. Very small flow can be measured. Various alarm functions: Battery voltage can alarm, empty tubes, or pipes that are not full of water, transducer fault alarm, and more. Low-power design and the use of high-energy batteries can work for 8 years and more. The communication interface is LoRaWAN or RS485 ModbusRTU. Dimensions Specification LoRaWAN Specification Data rate 250bps .. 5470bps Antenna Internal Antenna 2.67 dbi Battery 02 x AA size 1.5VDC, battery not included RF Frequency and Power 860..930Mhz, +14 .. +20 dBm, configurable for zones: EU868, IN865, RU864, KR920, AS923, AU915, US915 Protocol LoRaWAN class A Data sending modes interval time, alarm occurred and manually triggering by magnetic key RF Module complies to ETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD-T108 (Japan) Working temperature 1oC..+65oC Housing Polycarbonate plastic, IP68 Ordering codes Item code Descriptions UWM-15-LRW-8-01 Ultrasonic Water Meter DN15 with LoRaWAN connectivity, IP68, 860-870 Mhz for EU868, IN865, RU864 UWM-15-LRW-9-01 Ultrasonic Water Meter DN15 with LoRaWAN connectivity, IP68, 900-930 Mhz for KR920, AS923, AU915, US915 * Replace 15 by 20, 25, 32, 40 for different sizes Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com Bulk Ultrasonic Water Meter BUW SKU: BUW Doc No: BUW-DS-EN-10 Introduction BUW Bulk Ultrasonic water meter comprises the quality temperature sensor, the flow sensor, and a flow computer. The temperature sensor measures the temperature of the water and the flow sensor to measure the volume of water that flows through the pipelines by the transit time difference. The two data are sent to the flow computer after being collected, the consumption water quantity is worked out, stored, and indicated on the LCD finally. Dimension Drawings Features Ultrasonic water meter's intelligent measuring instrument consists of the temperature sensor, flow sensors, and flow computer; Could provide important application and data for many applications in the pipeline; Ultrasonic water meter is suitable for application environments requiring high range ratio(Q3/Q1)and forwards and reverse metering; The flow computer used sensor and through the time difference to collect temperature differences and sound waves to complete accurate measurement of water flow; And can provide important applications and data for many applications. Dimensions Specification LoRaWAN Specification Data rate 250bps .. 5470bps Antenna Internal Antenna 2.67 dbi Battery 02 x AA size 1.5VDC, battery not included RF Frequency and Power 860..930Mhz, +14 .. +20 dBm, configurable for zones: EU868, IN865, RU864, KR920, AS923, AU915, US915 Protocol LoRaWAN class A Data sending modes interval time, alarm occurred and manually triggering by magnetic key RF Module complies to ETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD-T108 (Japan) Working temperature 1oC..+65oC Housing Polycarbonate plastic, IP68 Ordering codes Item code Descriptions BUW-050-LRW-8-01 Bulk Ultrasonic Water Meter DN50 with LoRaWAN connectivity, IP68, 860-870 Mhz for EU868, IN865, RU864 BUW-050-LRW-9-01 Bulk Ultrasonic Water Meter DN50 with LoRaWAN connectivity, IP68, 900-930 Mhz for KR920, AS923, AU915, US915 * Replace 050 by 065 .. 300 for different sizes Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com Infrared Fever Scanner IFS-HQ1 SKU: IFS-HQ1 Doc No: IFS-HQ1-DS-EN-10 Introduction IFS-HQ1 is a cost effective tool to defend at the front line of Epidemic. It provides the simple method for fever scanning people in the crowd. Using a constant heat source for highest accuracy +/- 0.3 oC. Actual setup Features Extremely high accuracy +/- 0.3 oC; Non-contact thermal FEVER scanning for multiple people, max 20 people at the same time; Calibrate continuously with constant heat source; Calculate distance to compensate the temperature; Facial recognition algorithm for accurate and quick measurement; Thermal / Visual Imaging; AI Face recognition even with mask; Identify and record suspected infects: Time log, Face pictures, temperature values... Optional: connecting to cloudGlobiot for remote monitoring Dimensions Images view on Software (Windows) Thermal Image                                                                             Visual Image Specification Ordering codes Item code Descriptions IFS-HQ1-01 Infrared Fever Scanner for max 20 people, QVGA 384x288, 17μm, c/w Windows SW, Thermal + Visible imaging, USB3.0, Lens 9.7mm(f/1.0), Frame rate <30Hz, included Black body, NOT included stand and computer STAND-01 Tripod with Arm bar Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com pH Sensors Datasheet for all kinds of pH Sensor Process Flat pH Sensor H087 SKU: H087 Doc No: H087-DS-EN-10 Introduction H087 is a popular general purpose in-line (continuous measurement) electrode offering affordable, flat sensor application coverage for many water applications such as drinking water, industrial water, aquaculture, tank installations or related applications. The flat surface sensor is often referred to as "self-cleaning" when installed in a process stream since the water flow has a tendency to "shear off" biofouling and other debris from the sensor surface. 3/4" NPT threads on both front & back; Flat surface sensor with "self-cleaning" properties; Built-in temperature sensor Pt100. Typical applications Drinking water; Waste water; Industrial water; Aquaculture; Agriculture; Hydroponic; Soil pH measurement. Specification Sensing Technology Glass, combine electrode with Pt100 temperature sensor Measuring range pH 0 .. 14 Resolution pH 0.1 Accuracy +/- 0.1 Working temperature 0 .. 100 oC (compensated) Working pressure 0 .. 100 psig Process connection 3/4" NPT both ends Wetted parts PVC Sensor Cable 6m with BNC connector Rating IP68 Sensor Dimension D27 x 172 (mm) Sensor net weight < 200 grams Ordering Code Item code Descriptions H087-0020 PH SENSOR COMBO, IN-LINE, 3/4NPT PH COMBO, IN-LINE, CPVC, 3/4"NPT, ASGV FLAT, PT100 OHM, DJ, AG/AGCL, GEL, CE, 20F CABLE, BNC & T Link for full datasheet: https://filerun.daviteq.com/wl/?id=ZfgOqaUaPovTmC9NM9sragDDe60lrzbQ Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com Process pH Sensor PH12 SKU: H087 Doc No: PH12-DS-EN-10 Introduction PH12 is a popular general purpose in-line (continuous measurement) electrode offering affordable sensor application coverage for many water applications such as drinking water, industrial water, aquaculture, tank installations or related applications. 3/4" NPT threads on both front & back; Built-in temperature sensor Pt100. Typical applications Drinking water; Waste water; Industrial water; Aquaculture; Agriculture; Hydroponic; Soil pH measurement. Specification Sensing Technology Glass, combine electrode with Pt100 temperature sensor Measuring range pH 0 .. 14 Resolution pH 0.1 Accuracy +/- 0.1 Working temperature 0 .. 60 oC (compensated) Working pressure 0 .. 100 psig Process connection 3/4" NPT both ends Wetted parts PPS/PC Sensor Cable 5m with BNC connector Rating IP68 Sensor Dimension D27 x 172 (mm) Sensor net weight < 200 grams Ordering Code Item code Descriptions PH12-01 PH SENSOR COMBO, IN-LINE, 3/4NPT PH COMBO, IN-LINE, PPS/PC, 3/4"NPT, PT100, DJ, AG/AGCL, GEL, CE, 5m CABLE, BNC & T Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com WIND SPEED SENSOR WSP SKU: WSP Doc No: WSP-DS-EN-10 Introduction WSP is the Wind Speed Sensor with carbon fiber material. Sensor with high weather resistance, high durability, corrosion resistance and water resistance. Weather resistant; High durability; High data transmission efficiency and reliable. Typical applications Weather Station; Ship navigation; Aviation; Weather buoys; Wind turbines. Specification Measure range 0-70m/s( Other can be custom made) Start wind speed 0.2m/s Response time <0.5s Resolution 0.1m/s Accuracy ±(0.2+0.03V)m/s, V means wind speed Output 0..5VDC Power supply 12..24VDC Power consumption ≤0.3W Working temperature -20~60℃ Working humidity ≤100%RH Cable specifications 2m 3-wire system (analog signal) Ordering Code Item code Descriptions WSP-01-ANALOG WIND SPEED SENSOR, 0-70 M/S, CARBON FIBER, 0-5VDC OUTPUT, 12-24VDC, WITH CABLE AND CONNECTOR MBRTU-WSP-01 WIND SPEED SENSOR, CARBON FIBER CUPS, RS485/MODBUSRTU, 12-24VDC SUPPLY, 0-45M/S, IP65 Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com WIND DIRECTION SENSOR WDR SKU: WDR Doc No: WDR-DS-EN-10 Introduction The wind direction sensor is used to measure the direction value of the wind and convert it into an electrical signal, which can be directly transmitted to the recording device for processing. The sensor housing is made of polycarbonate environmental protection material, with very small dimensional tolerances and high surface accuracy. The wind direction sensor adopts low inertia wind vane and precision potentiometer, with high sensitivity and high precision. Weather resistant; High durability; High data transmission efficiency and reliable. Typical applications Weather Station; Ship navigation; Aviation; Weather buoys; Wind turbines. Specification Measure range 0-360 degree Start wind 0.5 m/s Resolution 0.1 degree Accuracy +/- 1 degree Maximum turning radius 200mm Output 0..5VDC or RS485 ModbusRTU Power supply 12..24VDC Power consumption ≤0.3W Working temperature -20~60℃ Working humidity ≤100%RH Cable specifications 2m 3-wire system (analog signal) Ordering Code Item code Descriptions WDR-01-ANALOG WIND DIRECTION SENSOR, 0-360 DEGREE, CARBON FIBER, 0-5VDC OUTPUT, 12-24VDC, WITH CABLE AND CONNECTOR MBRTU-WDR-01 WIND DIRECTION SENSOR, 0-360 DEGREE, CARBON FIBER, MODBUSRTU RS485 OUTPUT, 12-24VDC, IP65 Link for full datasheet: Link for manual: Daviteq Technologies Inc  www.daviteq.com   |     info@daviteq.com