SVF128 Vortex flow meter is a smart vortex flow meter utilizing “Karman vortex” theory to measure the velocity of fluid then calculate the flow rate in volume or mass. VFM128 is to use for various fluids such as gas, steam and liquid. The flow meter come with local or remote display and different type output such as 4-20mA, pulse, RS485 ModbusRTU, Hart for easily integrate into any PLC, SCADA, DCS system. The flow meter can be upgraded with latest wireless connectivity such as Sub-GHz, LoRaWAN, Sigfox, NB-IoT, 3G/4G... allow it to connect to any IoT platform such as Globiots, Azure, AWS...
Typical Applications: Saturated Steam, Super-heated Steam, Compressed Air, Liquid, Industrial Gases: Nitrogen, Oxygen... or Fuel Gas: Natural Gas...
Process Fluids | Liquid, Gas, Steam, Compressed Air |
Process connection | Flange or Wafer for size DN15~DN300 or 0.5 inch to 12 inch |
Local Display | Standard integral LCD display. Optional Remote display with 10m cable |
Measurable Parameters of standard version | Volumetric flow rates and totalizer, velocity. |
Measurable Parameters of Multi-variables version | Mass flow rate, volumetric flow rate, temperature, pressure, velocity. |
Output | Pulse, 4~20mA (HART V5, V7 @4~20mA), ModBus-RTU RS485 |
Process Pressure | 1.6MPa (232 psiG),2.5MPa (362 psiG),4.0MPa (580 psiG),6.3Mpa (913 psiG) for option |
Process Temperature | Standard type: -40 ~ 150 °C or -40 ~ 302 °F Medium type: -40 ~ 250 °C or -40 ~ 482 °F High temperature type: -40 ~ 350 °C or -40 ~ 662 °F |
Gas flow Turndown | DN15, DN20: Turndown ratio 10:1 DN25, DN32: Turndown ratio 15:1 DN40~DN300: Turndown ratio 30:1 |
Steam flow Turndown | DN15, DN20: Turndown ratio 11.6:1 DN25, DN32: Turndown ratio 17.5:1 DN40~DN300: Turndown ratio 35:1 |
Liquid flow Turndown | 23:1 |
Accuracy | Gas/Steam: ±1%RD(Re ≥ 20000), ±2%RD(10000 ‹ Re ‹ 20000) Liquid: ±0.75%RD(Re ≥ 20000), ±2%RD(10000 ‹ Re ‹ 20000) |
Repeatability | ±0.3% of flow reading, ±0.05 °C for temperature, ±0.05%FS of pressure |
Upstream/Downstream required | 15D / 5D |
Viscosity allowance | DN15 or 0.5 inch ≤ 4mPas DN25 or 1 inch ≤ 5mPas DN40~DN300 or 1.5~12 inch ≤ 7mPas |
Anti-vibration (both punch and fixed freq) | 0.5g |
Power Supply | 15.5 .. 42 VDC |
ITEM CODE | DESCRIPTIONS |
Select Vortex Type | |
SVF128-N SVF128-MV | Smart Vortex Flow meter, Standard version, NO temperature and pressure compensation Smart Vortex Flow meter, Standard version, WITH temperature and pressure compensation |
Fluid type | |
-1 or -2 or -3 | -1 for Liquid, -2 for Gas, -3 for Steam |
Process Connection | |
-WC -D1 -D2 -D3 -D4 -C1 -C2 -C3 -J1 -J2 -J3 | Wafer with carbon steel flanges up to 16 barG (232 psiG) (DN15 ~ DN300) Flanged DIN PN16 up to 16 barG (232 psiG) (DN15 ~ DN300) Flanged DIN PN25 up to 25 barG (362 psiG) (DN15 ~ DN300) Flanged DIN PN40 up to 40 barG (580 psiG) (DN15 ~ DN300) Flanged DIN PN63 up to 63 barG (913 psiG) (DN15 ~ DN300) Flanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch ~ 12 inch) Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch ~ 12 inch) Flanged ANSI CL400 up to 63 barG (913 psiG) (0.5 inch ~ 12 inch) JIS 10K up to 16 barG (232 psiG) (DN15 ~ DN300) JIS 20K up to 40 barG (580 psiG) (DN15 ~ DN300) JIS 30K up to 63 barG (913 psiG) (DN15 ~ DN300) |
Wetted Part Materials | |
-1 or -2 | -1 for 304SS, -2 for 316SS |
Degreased | |
- N or -D | -N for None, -D for Degreased for Oxygen Measurement |
Medium Temperature | |
-N or -S or -H | -N ≤ 150 °C, -S ≤ 250 °C, -H ≤ 350 °C |
Transmitter | |
-ML1 -ML3 -MR2 -NL1 -NL3 -NR3 | Integral transmitter, multi-variable, RS485, pulse Integral transmitter, multi-variable, RS485, pulse, 4 wire 4~20mA Remote transmitter (dual display), multi-variable, RS485, pulse, 4 wire 4~20mA, 10m cable Integral transmitter, RS485, pulse Integral transmitter, RS485, pulse, 4 wire 4~20mA Remote transmitter (dual display), RS485, pulse, 4 wire 4~20mA, 10m cable |
Cable Gland | |
-M -N | M20 x 1.5 1/2" NPT |
Other codes | |
-N -XXX | No Ex-proof Select size XXX = 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300 |
Optional Wireless Connectivities | Please specify: LoRaWAN, Sigfox, NB-IoT, 3G, 4G cat1, Sub-GHz |
Example | SVF128-MV-3-D1-1-N-S-MR2-M-N-080 AND provide us the process conditions for sizing to verify the flow meter size meet the process conditions. * Fluid type: * Flow min/normal/max: * Pressure min/normal/max: * Temperature min/normal/max: * Fluid viscosity: |