Payload WSSFC-AC | Firmware 3.0

1. Payload document is applied for the following products

Item code HW Version Firmware Version Remarks
WSSFC-AC-11 2H 3F  
       

2. Changes information in this version v.s previous version

Item Changes Changed by Changed Date Approved by Approved Date
1 Initial version D.Q.Tuan 24-06-2023 N.V.Loc 28-06-2023

The approved date is also the release date of this document.

3. Payload for Uplink messages

START_UP message
When? Purpose Wait for Downlink? LED color
This message will be sent once after 60 seconds from power-up the device To understand when was the device powered up NO

Blink

WHITE

Payload EVENT_ID HW_VERSION FW_VERSION LATEST_SIGFOX_DOWNLINK
bits 4 4 8 64
value 0b0000 = 0 yes yes yes
HEART_BEAT message
When? Purpose Wait for Downlink? LED color
This message will be sent in the pre-defined cycle, default is 24 hours To check the health status, get the current configuration, and send the new configuration to the device via downlink YES

Blink

GREEN

Payload EVENT_ID HW_VERSION FW_VERSION LATEST_SIGFOX_DOWNLINK
bits 4 4 8 64
value 0b0001 = 1 yes yes yes
PARAMETER_UPDATE message
When? Purpose Wait for Downlink? LED color

When the reed switch is activated by the magnet key.

How?

Move Magnet Key to the contact point of REED SWITCH.
Led blink SKY BLUE, hold Magnet Key 5s.
Led blink PURPLE, move Magnet Key away.

To send the new configuration to the device via downlink YES

Blink

PURPLE

Payload EVENT_ID HW_VERSION FW_VERSION LATEST_SIGFOX_DOWNLINK
bits 4 4 8 64
value 0b0010 = 2 yes yes yes
FORCE_DATA message
When? Purpose Wait for Downlink? LED color

When the reed switch is activated by the magnet key.

How?

Move Magnet Key to the contact point of REED SWITCH.
Led blink SKY BLUE, move Magnet Key away.
To get the instant measured value from the device for calibration and validation. NO

Blink

SKY BLUE

Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved AC_Current RAW_VALUE
bits 4 1 3 2 2 4 32 32
value 0b0011 = 3 yes zeros yes yes zeros yes yes
CYCLIC_DATA message
When? Purpose Wait for Downlink? LED color
This message will be sent in the pre-defined cycle. To get the measured value from the device in the pre-defined cycle. NO

Blink

SKY BLUE

Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved AC_Current Tentative
bits 4 1 3 2 2 4 32 8
value 0b0100 = 4 yes zeros yes yes zeros yes yes
ALARM message
When? Purpose Wait for Downlink? LED color
This message will be sent upon the alarm occurs. Sensor_sampling_rate will determine the processing delay of the alarm. To get the instant measured value upon the measured value was passing a threshold. NO

Blink

RED

Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved AC_Current Tentative
bits 4 1 3 2 2 4 32 8
value 0b0101 = 5 yes zeros yes yes zeros yes yes

4. Payload Fields of Uplink

Below is explanation about the payload fields in the uplink messages.

Data name

Description

Encoding or Possible values

Length

(in bits)

EVENT_ID

Unique ID identifying the device event

4-bit unsigned integer

0 = START_UP

1 = HEARTBEAT

2 = PARAMETERS_UPDATE

3 = FORCE_DATA

4 = CYCLIC_DATA

5 = ALARM

4

HW_VERSION

Indicate HW  version

4-bit unsigned integer

1..15

4

FW_VERSION

Indicate FW version

8-bit unsigned integer

1..255

8

LATEST_SIGFOX_DOWNLINK

Latest received and valid sigfox downlink frame

= Current configuration

64-bit encoded field

See Sigfox Downlink tab

64

HW_ERROR

HW error

0b0 = no error

0b1 = error

1

ALARM

Alarm

0b00 = no alarm

0b01 = low alarm

0b10 = high alarm

0b11 = not used

2

BATTERY_LEVEL

Battery level

2-bit unsigned integer

0 to 3

0: 10%

1: 30%

2: 60%

3: 99%

2

AC_CURRENT

AC current in Ampere (after multiplying the CT ratio)

32-bit float

32

RAW_VALUE

Raw value of main parameter

32-bit float

32

TENTATIVE

Tentative number
* this number to count how many uplink messages were sent since the alarm happened.

8-bit unsigned integer

Formula: (8-bit_Tentative +1)= real_tentative #

Range: 1 to 256

Accuracy: 1

Example: 0b00000111 = 0x7=7=> 7+1 =>tentative # 8

8

Users can use a downlink message to change the configuration of the device. There are 02 types of downlink messages:

Payload

HIGH_ALARM_SETPOINT

LOW_ALARM_SETPOINT_FACTOR

ALARM_ENABLE

ALARM_PERIOD

LED_BUZZER_ENABLE

HEARTBEAT_PERIOD

MEASURE_PERIOD

TX_REPEAT

CYCLIC_DATA_PERIOD

DEVICE_RESET

DOWNLINK_TYPE

bits

32

8

1

3

1

3

4

1

3

4

4

Value

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

0b0000 = 0

Below is the table to explain in detail the meaning of each configuration parameter and its default value.

Parameter

Description

Possible values

Default value

Length

(in bits)

HIGH_ALARM_SETPOINT

High alarm setpoint for

calculated value

32-bit float value

1000000000

32

LOW_ALARM_SETPOINT_FACTOR

Low alarm setpoint for

calculated value

8-bit unsigned integer

LOW_ALARM_SETPOINT = HIGH_ALARM_SETPOINT *  LOW_ALARM_SETPOINT_FACTOR / 200

0

8

ALARM_ENABLE

Enable/Disable ALARM event

0b0 = ALARM event is OFF

0b1 = ALARM event is ON

0b0 = ALARM event is OFF

1

ALARM_PERIOD

Period of time to send

ALARM event
* when alarm occurs, the device will send uplink alarm message in every ALARM_PERIOD cycle, until the Alarm is end.

0b000 = every  10min

0b001 = every  30min

0b010 = every 1h

0b011 = every 2h

0b100 = every 3h

0b101 = every 6h

0b110 = every 12h

0b111 = every 24h

0b000 = every  10min

3

LED_BUZZER_ENABLE

Enable/Disable LEDs and

Buzzers interactions for action

not triggered by the reed switch

0b0 = LEDs and Buzzers are OFF

0b1 = LEDs and Buzzers are ON

0b1 = LEDs and Buzzers are ON

1

HEARTBEAT_PERIOD

Period of time to send

HEARTBEAT event

0b000 = every  1h

0b001 = every  6h

0b010 = every 12h

0b011 = every 24h (1 day)

0b100 = every 48h (2 days)

0b101 = every 72h (3 days)

0b110 = every 120h (5 days)

0b111 = every 240h (10 days)

0b011 = every 24h (1 day)

3

MEASURE_PERIOD

Period of time to measure

sensor

0b0000 = every 1s

0b0001 = every 2s

0b0010 = every 5s

0b0011 = every 10s

0b0100 = every 20s

0b0101 = every 30s

0b0110 = every 1min

0b0111 = every 2min

0b1000 = every 5min

0b1001 = every 10min

0b1010 = every 20min

0b1011 = every 30min

0b1100 = every 1h

0b1101 = every 2h

0b1110 = every 3h

0b1111 = every 6h

0b1001 = every 10min

4

TX_REPEAT

Sigfox TX repeat

0b0 = Send RF 1 time

0b1 = Send RF 3 time

0b1 = Send RF 3 time

1

CYCLIC_DATA_PERIOD

Period of time to send

CYCLIC_DATA event

0b000 = every  10min

0b001 = every  30min

0b010 = every 1h

0b011 = every 2h

0b100 = every 3h

0b101 = every 6h

0b110 = every 12h

0b111 = every 24h

0b000 = every 10min

3

DEVICE_RESET

Once this parameter is set, the device shall restart once after having received the Downlink.

0b1010 = 0xA = force device reset

others = do nothing

0b0000 = do nothing

4

DOWNLINK_TYPE

Downlink type

4-bit unsigned integer

See Sigfox Downlink tab

0b0000

4

Parameter

Setting value

(in decimal)

Setting Value (in binary)

Length

(in bits)

HIGH_ALARM_SETPOINT

1000000000

00111011100110101100101000000000

32

LOW_ALARM_SETPOINT_FACTOR

0

00000000

8

ALARM_ENABLE

 

0

1

ALARM_PERIOD

 

000

3

LED_BUZZER_ENABLE

 

1

1

HEARTBEAT_PERIOD

 

011

3

MEASURE_PERIOD

 

1011

4

TX_REPEAT

 

1

1

CYCLIC_DATA_PERIOD

 

010

3

DEVICE_RESET

 

0000

4

DOWNLINK_TYPE

 

0000

4

Then you will get the final configuration code as below:

0011 1011 1001 1010 1100 1010 0000 0000 0000 0000 0000 1011 1011 1010 0000 0000 = 3B9ACA00000BCA00

With this downlink, the user can write the configuration to any address on the memory map of the device. Please refer to the memory map of the device to understand what parameters can be written.

The length of the configuration parameter can be 1, 2 bytes, or 4 bytes, but the total length of the Downlink payload must equal 64 bits (8 bytes). Please see below the downlink format for both types.

Payload

PRM_ADDRESS

PRM_LENGTH

PRM_VALUE

reserved

DOWNLINK_TYPE

bits

8

8

16

28

4

Value

yes

0x02 = 2

yes

zeros

0b0101 = 5

Payload

PRM_ADDRESS

PRM_LENGTH

PRM_VALUE

reserved

DOWNLINK_TYPE

bits

8

8

32

12

4

Value

yes

0x04 = 4

yes

zeros

0b0101 = 5

Where:

  • PRM_ADDRESS: address of the configuration parameter in the memory map of the device;
  • PRM_LENGTH: is the length of that parameter, in bytes;
  • PRM_VALUE: is the value the user wants to write to that parameter;
  • reserved: a series of bits of zero to fulfill the downlink so that it has the total length = 64 bits (8 bytes)

Note: the total length of down link must be equal 8 bytes

PARAMETER

DATA TYPE OF PARAMETER

PRM_ADDRESS

PRM_LENGTH

PRM_VALUE

DOWNLINK_TYPE

PAYLOAD OF DOWNLINK (IN HEXA)

(bytes)

 

1

1

4

2

8

CONSTANT_A

Float

0x16

0x04 = 4

0x3F8CCCCD = 1.1

0x0005

16043F8CCCCD0005

CONSTANT_B

Float

0x18

0x04 = 4

0x3E4CCCCD = 0.2

0x0005

18043E4CCCCD0005

HIGH_CUT

Float

0x1A

0x04 = 4

0x447A0000 = 1000

0x0005

1A04447A00000005

LOW_CUT

Float

0x1C

0x04 = 4

0x00000000 = 0

0x0005

1C04000000000005

SENSOR_BOOT_TIME

Uint32

0x1E

0x04 = 4

0x000000C8 = 200

0x0005

1E04000000C80005

CT

Float

0x32

0x04 = 4

0x42200000 = 40

0x0005

3204422000000005

5.3 Free online data conversion tools

6. Reed switches

The Sigfox-ready sensor normally comes with at least 1 reed switch for user manipulation during commissioning or maintenance.

Some other versions come with 02 reed switches.

The WSSFC-AC comes with 1 reed switch, please find below the functions of this switch.

EVENT

PRE-CONDITION

ACTION

LED STATUS

ACTIVITIES

POST-CONDITION

FORCE_DATA

Any state

Move Magnet Key to the contact point of REED SWITCH.

Led blink SKY BLUE, move Magnet Key away.

Blink SKY BLUE

the device will send the uplink message FORCE_DATA

Back to the previous state

PARAMETERS_UPDATE

Any state

Move Magnet Key to the contact point of REED SWITCH.

Led blink SKY BLUE, hold Magnet Key 5s.

Led blink PURPLE, move Magnet Key away.

Blink PURPLE

the device will send the uplink message PARAMETER_UPDATE and wait for a new downlink to get the new configuration

Back to the previous state