Process Free Chlorine Sensor with Analog output A420-FCL
SKU: A420-FCL | Doc No: A420-FCL-DS-EN-10 |
IntroductionA420-FCL Free Chlorine Sensor is an excellent choice for continuous measurement of free (or residual) chlorine in swimming pools, spas, industrial applications, or dirty/colored samples where colorimetric methods are inadequate. This electrode utilizes 2-electrode ampero-metric measurement technology and the measured chlorine concentration is compensated by an internal temperature sensor. Analog output 4-20mA allow easily integrate into any Monitoring or Control systems.
|
Typical ApplicationsA420-FCL can be used to monitor or control the residual chlorine in:
Swimming pools; SPAs; Industrial Process; Municipal Water; ... |
Specification
Sensing Technology |
Two-electrode amperometric technology with gas permeable membranes (replaceable) |
Measuring range | 0-10mg/L or 0-20mg/L |
Accuracy & Resolution | +/- 0.1 mg/L |
Repeatability | +/- 0.05 mg/L (25 oC) |
Response Time | T90 < 90s (25 oC) |
Working Condition | 0 .. 50 oC with pH = 5 .. 9 |
Working Pressure | 0 .. 15 psig |
Flow range | 30 .. 60 L/h or 0.6 .. 1.3 cm/s |
Output | 4-20mA |
Power supply | 6..12VDC, avg. < 200mA |
Conditioning |
New, first start-up: at least 4hours Restart-up: < 30 min. |
Calibration |
One Point - Manual with DPD |
Interferences |
ClO2, Ozone, Bromine Cyanuric Acid compatible |
Process connection | 1/2" NPT |
Wetted parts |
PVC, Silicone, ABS, PES |
Sensor Cable | 6m with BNC connector |
Rating | IP68 |
Sensor Dimension | D21.3 x 219 (mm) |
Sensor net weight | < 200 grams |
Warranty | 1 year for probe, membrane for 03 months |
Ordering Code
Item code | Descriptions |
A420-FCL-01 |
PROCESS RESIDUAL CHLORINE SENSOR WITH TEMPERATURE COMPENSATION, 0-10MG/L, IP68, 1/2" NPT SUBMERSIBLE, 4-20MA OUTPUT, 6-12VDC |
A420-FCL-02 |
PROCESS RESIDUAL CHLORINE SENSOR WITH TEMPERATURE COMPENSATION, 0-20MG/L, IP68, 1/2" NPT SUBMERSIBLE, 4-20MA OUTPUT, 6-12VDC |
Replaceable spare-parts |
|
RC66-MEM1 |
CHLORINE SENSOR MEMBRANE RC66 |
RF0CR2-125 |
CHLORINE INTERNAL FILLING GEL RC66, 125 ML |