DAVITEQ NITROGEN DIOXIDE NO2 GAS SENSOR, 20 PPM, SERI-4
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Sensor type | Daviteq Seri-4 electro-chemical gas sensor |
Nominal range | 0-20 ppm |
Maximum overload | 40 ppm |
Filter | Inboard filter to remove acidic gases |
Resolution | 0.1 ppm |
T90 response time | < 40 s |
Typical Baseline Range (pure air, 20°C) |
-0.1 ppm .. + 0.2 ppm |
Repeatability | < 2% of reading |
Accuracy | +/- 5% of reading |
Zero Stability | 0 .. 0.2 ppm in pure Air, 20oC |
Temperature compensation | Yes |
WORKING CONDITIONS | |
Relative humidity range |
15 % to 90 % RH non-condensing |
Temperature range |
-40 °C to 50 °C |
Pressure range |
Atmospheric ± 10% |
SENSOR LIFETIME | |
Expected Operation Life |
2 years in the air |
Expected Long Term Output Drift in air |
< 2 % of reading loss per month |
CROSS SENSITIVITY DATA
Interfering Gas |
Concentration (ppm) | Reading (ppm) |
C2H4 |
100 | 0 |
CH2O |
7 | 0 |
Cl2 |
20 | 15 |
CO |
100 | 0 |
ETHANOL (C2H5OH) |
60 | 0 |
H2 |
100 | 0 |
H2S |
20 | < - 20 |
HCL |
20 | 0 |
NH3 |
80 | 0 |
NO |
50 | 0 |
O3 |
1 | 1 |
SO2 |
5 | 0 |
No Comments