Instructions for Grounding of Pressure Sensor

DEC-2022

CONNECTING GND FOR SENSOR

Step 1: Open the blue housing of the sensor

modbus-config-H4.png

Step 2: Locate the GND point on the PCB (same GND point of Battery);

20221207_063401713_iOS.png

Step 3: Solder a wire to this GND point; the other end of the wire will be screwed to 1 of 2 screws on the aluminum base;

MicrosoftTeams-image-(193).jpeg

Step 4: Outside of the aluminum base there is another screw → make a wire connection from this screw to the body of pressure sensor (stainless steel cylindrical body) → Use a hose clamp or stainless steel pipe bracket to lock the connection between the wire and the housing.

20221207_065555132_iOS.png

Support contacts

Manufacturer

logo-01.png

Daviteq Technologies Inc
No.11 Street 2G, Nam Hung Vuong Res., An Lac Ward, Binh Tan Dist., Ho Chi Minh City, Vietnam.
Tel: +84-28-6268.2523/4 (ext.122)

Email: info@daviteq.com | www.daviteq.com