HIGH PERFORMANCE GAS MEASUREMENT MODULE MAX-O3
Item code: MAX-O3-C5
Description: Internal Sensor module for measuring Ozone gas.
Used for: MAQM-MAX
SENSOR SPECIFICATION
MEASURING SPECIFICATION | |
Measuring technology | Electro-chemical |
Measurement range | 0-5 ppm |
Overload | 50 ppm |
Resolution | 0.001 ppm |
Lower Detectable Limit | 0.001 ppm |
Accuracy | +/- 2% of Reading value |
Linearity |
< 0.1% of Full scale |
Response Time (T80) | < 60s |
Operating Pressure | Atmospheric ± 10% |
Working Temperature | -40 .. + 50 oC |
Working Humidity | 15..90% RH non-condensing, continuous |
Sensor Life Time | 2 years in clean air |
Drift in Air | < 2 % signal loss per month |
Power supply | 9..36VDC, max 30mA |
CROSS SENSITIVITY DATA
The table below does not claim to be complete. Interfering gases should not be used for calibration.
Important Application Notes: NO readily forms NO2 in the presence of O2.