| No. |
Phenomena |
Reason |
Solution |
|---|
| 1 |
The wireless transmitter is still running and sending data, however, all the measurement parameters are not updated with new values |
The connection between the AG tilt sensor and the wireless transmitter is broken |
Contact the manufacturer for repair or replacement |
| The battery is almost draining off |
Check the battery status and replace it when necessary |
| 2 |
The measured values are not as expected |
The installation direction is not correct |
Re-check the installation |
| The sensor is drifting |
Contact the manufacturer for repair or replacement |
| The calibration position or calibration process is incorrect |
Re-calibrate the device with right position and right process |
| 3 |
The reading values are very noisy even though the sensor is in a standstill position. |
The sensor AG tilt sensor got a problem |
Contact the manufacturer for repair or replacement |
| External factors at installation location such as wind, vibration, temperature, sun, heat might affect the tilt value |
External factors such as wind, vibration, temperature, sun, heat at installation location |
| 4 |
The value of HW_Error equal 1 |
The lost connection between the AG sensor and the wireless transmitter |
Contact the manufacturer for repair or replacement |
| The sensor AG sensor got a problem |
Contact the manufacturer for repair or replacement |
No Comments